{"id":902,"date":"2026-08-02T15:12:47","date_gmt":"2026-08-02T15:12:47","guid":{"rendered":"https:\/\/lumexislaser.com\/?page_id=902"},"modified":"2026-08-05T10:47:26","modified_gmt":"2026-08-05T10:47:26","slug":"ranging-laser-sources","status":"publish","type":"page","link":"https:\/\/lumexislaser.com\/es\/solutions\/ranging-laser-sources\/","title":{"rendered":"1535 nm Er:Glass Laser Sources for Precision Ranging Systems"},"content":{"rendered":"<style>\nbody.page-id-902{overflow-x:clip}\nbody.page-id-902 .page-header,body.page-id-902 h1.entry-title{display:none!important}\nbody.page-id-902 .lumexis-solution-hero>.wp-block-columns{width:100%!important;max-width:1140px!important;margin-left:auto!important;margin-right:auto!important;align-items:stretch}\nbody.page-id-902 .lumexis-solution-hero .wp-block-column:last-child{display:flex}\nbody.page-id-902 .lumexis-solution-hero .wp-block-column:last-child figure{display:grid;grid-template-rows:minmax(0,1fr) auto;width:100%;height:100%;margin:0}\nbody.page-id-902 .lumexis-solution-hero .wp-block-column:last-child img{width:100%;height:100%;min-height:0;object-fit:cover}\nbody.page-id-902 .lumexis-visual-card{width:100%!important;max-width:1140px!important;margin-left:auto!important;margin-right:auto!important;overflow:hidden;box-shadow:0 14px 34px rgba(17,24,39,.06)}\nbody.page-id-902 .lumexis-visual-card .wp-block-image,body.page-id-902 .lumexis-visual-card figure{margin:0;height:100%}\nbody.page-id-902 .lumexis-visual-card img{width:100%;height:100%;min-height:300px;object-fit:cover}\nbody.page-id-902 .lumexis-solution-table{overflow-x:auto}\nbody.page-id-902 .lumexis-solution-table table{min-width:760px}\n@media(max-width:781px){body.page-id-902 .lumexis-solution-hero .wp-block-column:last-child figure{display:block;height:auto}body.page-id-902 .lumexis-solution-hero .wp-block-column:last-child img,body.page-id-902 .lumexis-visual-card img{height:auto;min-height:0}}\n<\/style>\n\n<div class=\"wp-block-group alignfull lumexis-solution-hero has-background is-layout-constrained wp-container-core-group-is-layout-c12f9e37 wp-block-group-is-layout-constrained\" style=\"background-color:#0b0b0d;margin-top:0;margin-bottom:0;padding-top:72px;padding-right:24px;padding-bottom:72px;padding-left:24px\">\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-bf561b98 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:55%\">\n<p class=\"has-text-color wp-block-paragraph\" style=\"color:#c9a24b;margin-bottom:18px;font-size:12px;font-weight:700;letter-spacing:0.12em;text-transform:uppercase\">Fuentes l\u00e1ser de telemetr\u00eda<\/p>\n\n<h1 class=\"wp-block-heading has-text-color\" style=\"color:#ffffff;margin-bottom:24px;font-size:clamp(28px,3vw,40px);font-weight:600;line-height:1.12\">Fuentes l\u00e1ser de telemetr\u00eda: dise\u00f1adas en torno al presupuesto de alcance<\/h1>\n\n<p class=\"has-text-color wp-block-paragraph\" style=\"color:#d5d5d2;margin-bottom:28px;font-size:15px;line-height:1.7\">Lumexis desarrolla un compacto de 1535 nm <a href=\"https:\/\/lumexislaser.com\/es\/erbium-glass-lasers\/\">Fuentes l\u00e1ser de Er:glass<\/a> para telemetr\u00eda pulsada de tiempo de vuelo, con configuraciones de fuente seleccionadas en funci\u00f3n del objetivo, la distancia de trabajo, la \u00f3ptica, la sincronizaci\u00f3n, el receptor y los l\u00edmites de integraci\u00f3n OEM.<\/p>\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-font-size\" style=\"font-size:13px;font-weight:700\"><a class=\"wp-block-button__link has-text-color has-background wp-element-button\" href=\"https:\/\/lumexislaser.com\/es\/contact\/\" style=\"border-radius:2px;color:#0b0b0d;background-color:#c9a24b\">Discuta su aplicaci\u00f3n con Lumexis<\/a><\/div>\n<\/div><\/div>\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:45%\">\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"900\" height=\"600\" src=\"https:\/\/lumexislaser.com\/wp-content\/uploads\/2026\/08\/1535nm-ranging-laser-source-hero.webp\" alt=\"Fuente l\u00e1ser compacta Lumexis de 1535 nm Er:glass con una ruta \u00f3ptica conceptual de telemetr\u00eda por tiempo de vuelo\" class=\"wp-image-901\" srcset=\"https:\/\/lumexislaser.com\/wp-content\/uploads\/2026\/08\/1535nm-ranging-laser-source-hero.webp 900w, https:\/\/lumexislaser.com\/wp-content\/uploads\/2026\/08\/1535nm-ranging-laser-source-hero-300x200.webp 300w, https:\/\/lumexislaser.com\/wp-content\/uploads\/2026\/08\/1535nm-ranging-laser-source-hero-768x512.webp 768w, https:\/\/lumexislaser.com\/wp-content\/uploads\/2026\/08\/1535nm-ranging-laser-source-hero-600x400.webp 600w\" sizes=\"(max-width: 900px) 100vw, 900px\" \/><\/figure>\n<\/div><\/div><\/div>\n<div class=\"wp-block-group alignfull has-background is-layout-constrained wp-container-core-group-is-layout-c12f9e37 wp-block-group-is-layout-constrained\" style=\"background-color:#ffffff;margin-top:0;margin-bottom:0;padding-top:72px;padding-right:24px;padding-bottom:72px;padding-left:24px\">\n<p class=\"wp-block-paragraph\">Dise\u00f1e el transmisor en torno al presupuesto de alcance requerido, no solo a la energ\u00eda del pulso.<\/p>\n\n<p class=\"wp-block-paragraph\">Lumexis desarrolla y fabrica fuentes l\u00e1ser compactas de Er:glass de 1535 nm para telemetr\u00eda pulsada de tiempo de vuelo (ToF). La cartera abarca desde <strong>40 a 500 \u00b5J<\/strong>, <strong>3\u20136 ns<\/strong> ancho de pulso y configuraciones desde <strong>1\u201310 Hz<\/strong> hasta <strong>1000 Hz<\/strong>, lo que brinda a los equipos de instrumentaci\u00f3n un punto de partida pr\u00e1ctico para telemetr\u00eda compacta, medici\u00f3n asistida por c\u00e1mara, instrumentos de campo, medici\u00f3n cient\u00edfica y subsistemas \u00f3pticos OEM.<\/p>\n\n<p class=\"wp-block-paragraph\">A <strong>Fuente l\u00e1ser de 1535 nm para telemetr\u00eda l\u00e1ser<\/strong> debe seleccionarse como una parte del enlace transmisor-receptor. Por lo tanto, esta p\u00e1gina comienza con la adecuaci\u00f3n a la aplicaci\u00f3n y los par\u00e1metros exactos de la fuente, y luego conecta esos valores con las decisiones de \u00f3ptica, sincronizaci\u00f3n, detecci\u00f3n e integraci\u00f3n.<\/p>\n\n<p class=\"wp-block-paragraph\">Para seleccionar una fuente r\u00e1pidamente, env\u00edenos seis datos:<\/p>\n\n<ol class=\"wp-block-list\">\n<li>material del objetivo, tama\u00f1o, \u00e1ngulo y reflectividad esperada;<\/li>\n<li>distancia de trabajo normal y m\u00e1xima;<\/li>\n<li>tasa de medici\u00f3n o actualizaci\u00f3n requerida;<\/li>\n<li>l\u00edmites de apertura de transmisi\u00f3n y divergencia final del haz;<\/li>\n<li>l\u00edmites de envolvente, masa, voltaje y temperatura de la fuente;<\/li>\n<li>apertura del receptor, tipo de detector y arquitectura de sincronizaci\u00f3n.<\/li>\n<\/ol>\n\n<p class=\"wp-block-paragraph\"><strong>Ruta m\u00e1s r\u00e1pida:<\/strong> <a href=\"#request-a-source-recommendation\">Env\u00ede su presupuesto de alcance y l\u00edmites de integraci\u00f3n para una recomendaci\u00f3n de fuente<\/a>.<\/p>\n<\/div>\n\n<div class=\"wp-block-group alignfull has-background is-layout-constrained wp-container-core-group-is-layout-c12f9e37 wp-block-group-is-layout-constrained\" style=\"background-color:#f5f5f3;margin-top:0;margin-bottom:0;padding-top:72px;padding-right:24px;padding-bottom:72px;padding-left:24px\">\n<h2 class=\"wp-block-heading\" style=\"margin-top:0;margin-bottom:32px;font-size:clamp(30px,4vw,44px);font-weight:700;line-height:1.08\">Comience con la aplicaci\u00f3n de telemetr\u00eda<\/h2>\n\n<div class=\"wp-block-group alignwide lumexis-visual-card has-border-color has-background is-layout-constrained wp-block-group-is-layout-constrained\" style=\"border-color:#dedede;border-width:1px;border-radius:2px;background-color:#ffffff;margin-top:34px;margin-bottom:34px\">\n<div class=\"wp-block-columns are-vertically-aligned-stretch is-layout-flex wp-container-core-columns-is-layout-946c1612 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-stretch is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:58%\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" src=\"https:\/\/lumexislaser.com\/wp-content\/uploads\/2026\/08\/1535nm-ranging-applications.webp\" alt=\"Cuatro aplicaciones para fuentes l\u00e1ser de telemetr\u00eda de 1535 nm: telemetr\u00eda compacta, medici\u00f3n asistida por c\u00e1mara, instrumentos de campo y sistemas cient\u00edficos de tiempo de vuelo.\"\/><\/figure>\n<\/div>\n\n<div class=\"wp-block-column is-vertically-aligned-stretch is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:42%\">\n<div class=\"wp-block-group is-layout-constrained wp-container-core-group-is-layout-b2c065c3 wp-block-group-is-layout-constrained\" style=\"padding-top:clamp(28px,4vw,48px);padding-right:clamp(24px,4vw,48px);padding-bottom:clamp(28px,4vw,48px);padding-left:clamp(24px,4vw,48px)\">\n<p class=\"has-text-color wp-block-paragraph\" style=\"color:#a17d2f;margin-bottom:12px;font-size:11px;font-weight:700;letter-spacing:0.12em;text-transform:uppercase\">Adecuaci\u00f3n a la aplicaci\u00f3n<\/p>\n\n<h3 class=\"wp-block-heading\" style=\"margin-top:0;margin-bottom:14px;font-size:clamp(22px,2.4vw,30px);font-weight:650;line-height:1.2\">Adapte la fuente \u00f3ptica a la tarea de medici\u00f3n real<\/h3>\n\n<p class=\"has-text-color wp-block-paragraph\" style=\"color:#4c5157;margin-bottom:0;font-size:14px;line-height:1.7\">Cuatro aplicaciones para fuentes l\u00e1ser de telemetr\u00eda de 1535 nm: telemetr\u00eda compacta, medici\u00f3n asistida por c\u00e1mara, instrumentos de campo y sistemas cient\u00edficos de tiempo de vuelo.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<figure class=\"wp-block-table alignwide is-style-stripes lumexis-solution-table\"><table>\n<thead>\n<tr>\n<th>Aplicaci\u00f3n<\/th>\n<th>Lo que aporta la fuente de 1535 nm<\/th>\n<th>Lo que debe a\u00f1adir el sistema final<\/th>\n<th>Inicie la solicitud de cotizaci\u00f3n con<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Tel\u00e9metros \u00f3pticos compactos<\/td>\n<td>Un pulso \u00f3ptico corto para medici\u00f3n directa de ToF<\/td>\n<td>controlador de fuente, \u00f3ptica de transmisi\u00f3n, receptor, electr\u00f3nica de sincronizaci\u00f3n, carcasa, interfaz<\/td>\n<td>envolvente de distancia, objetivo, apertura, tasa, paquete<\/td>\n<\/tr>\n<tr>\n<td>Medici\u00f3n civil asistida por c\u00e1mara<\/td>\n<td>Un canal de alcance a lo largo de una l\u00ednea de visi\u00f3n calibrada<\/td>\n<td>alineaci\u00f3n c\u00e1mara-l\u00e1ser, selecci\u00f3n de objetivo, datos de pose o apuntado, procesamiento del host<\/td>\n<td>campo de visi\u00f3n de la c\u00e1mara, l\u00ednea de mira, tama\u00f1o del objetivo, latencia<\/td>\n<\/tr>\n<tr>\n<td>Instrumentos de mano y de campo<\/td>\n<td>Emisi\u00f3n pulsada compacta para topograf\u00eda, inspecci\u00f3n de activos y mediciones cient\u00edficas de campo<\/td>\n<td>interfaz de usuario, gesti\u00f3n de energ\u00eda, m\u00e9todo de apuntado, receptor, calibraci\u00f3n<\/td>\n<td>tasa de actualizaci\u00f3n, temperatura de operaci\u00f3n, presupuesto de bater\u00eda, distancia m\u00e1s cercana<\/td>\n<\/tr>\n<tr>\n<td>Instrumentos cient\u00edficos de ToF<\/td>\n<td>Un pulso nanosegundo controlado para experimentos de sincronizaci\u00f3n y mediciones remotas<\/td>\n<td>definici\u00f3n de disparo, referencia de emisi\u00f3n, cadena de detecci\u00f3n, adquisici\u00f3n de datos, an\u00e1lisis de incertidumbre<\/td>\n<td>referencia de sincronizaci\u00f3n, tasa de repetici\u00f3n, ancho de banda del detector, registro<\/td>\n<\/tr>\n<tr>\n<td>subsistemas \u00f3pticos OEM<\/td>\n<td>Un bloque de construcci\u00f3n de fuente que puede empaquetarse en torno a \u00f3ptica y electr\u00f3nica espec\u00edficas del proyecto<\/td>\n<td>datum mec\u00e1nico, ruta t\u00e9rmica, accionamiento el\u00e9ctrico, aislamiento \u00f3ptico, calificaci\u00f3n<\/td>\n<td>envolvente de volumen, montaje, voltaje, perfil de vida \u00fatil, plan de pruebas<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/figure>\n\n<h3 class=\"wp-block-heading\" style=\"margin-top:34px;margin-bottom:16px;font-size:clamp(21px,2.4vw,28px);font-weight:650;line-height:1.25\">Qu\u00e9 es este producto y qu\u00e9 no es<\/h3>\n\n<p class=\"wp-block-paragraph\">La fuente l\u00e1ser de Er:glass es el <strong>emisor dentro de un transmisor de alcance<\/strong>. Crea el pulso \u00f3ptico, pero por s\u00ed mismo no calcula la distancia ni proporciona un canal de medici\u00f3n de alcance completo.<\/p>\n\n<p class=\"wp-block-paragraph\">Un tel\u00e9metro funcional tambi\u00e9n requiere:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>un circuito de bombeo y excitaci\u00f3n compatible;<\/li>\n<li>control de disparo y una referencia de tiempo de emisi\u00f3n definida;<\/li>\n<li>\u00f3ptica de colimaci\u00f3n o expansi\u00f3n del haz;<\/li>\n<li>una trayectoria hacia el objetivo y una ventana externa adecuada;<\/li>\n<li>\u00f3ptica de recepci\u00f3n y filtrado espectral;<\/li>\n<li>un detector InGaAs y una cadena de receptor de bajo ruido;<\/li>\n<li>electr\u00f3nica de temporizaci\u00f3n, detecci\u00f3n, validaci\u00f3n e interfaz con el host.<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Esta distinci\u00f3n es importante en la adquisici\u00f3n. Una hoja de datos de la fuente debe compararse con otras fuentes. Un tel\u00e9metro completo debe compararse por alcance condicionado al objetivo, alcance m\u00ednimo, precisi\u00f3n, comportamiento de medici\u00f3n v\u00e1lida, interfaz, empaque y rendimiento ambiental.<\/p>\n<\/div>\n\n<div class=\"wp-block-group alignfull has-background is-layout-constrained wp-container-core-group-is-layout-c12f9e37 wp-block-group-is-layout-constrained\" style=\"background-color:#ffffff;margin-top:0;margin-bottom:0;padding-top:72px;padding-right:24px;padding-bottom:72px;padding-left:24px\">\n<h2 class=\"wp-block-heading\" style=\"margin-top:0;margin-bottom:32px;font-size:clamp(30px,4vw,44px);font-weight:700;line-height:1.08\">Haga coincidir la plataforma de fuente Lumexis<\/h2>\n\n<p class=\"wp-block-paragraph\">La tabla siguiente es una gu\u00eda de selecci\u00f3n inicial. Los valores son especificaciones nominales de la plataforma del producto; confirme el dibujo espec\u00edfico del pedido, las condiciones de operaci\u00f3n y los criterios de aceptaci\u00f3n antes de la liberaci\u00f3n mec\u00e1nica o el\u00e9ctrica.<\/p>\n\n<figure class=\"wp-block-table alignwide is-style-stripes lumexis-solution-table\"><table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th style=\"text-align: right;\">Longitud de onda<\/th>\n<th style=\"text-align: right;\">Energ\u00eda de pulso<\/th>\n<th style=\"text-align: right;\">Tasa de repetici\u00f3n<\/th>\n<th style=\"text-align: right;\">Ancho de pulso<\/th>\n<th style=\"text-align: right;\">Divergencia de la fuente<\/th>\n<th style=\"text-align: right;\">Voltaje de alimentaci\u00f3n<\/th>\n<th style=\"text-align: right;\">Temperatura de operaci\u00f3n<\/th>\n<th style=\"text-align: right;\">Masa<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1535-LXER040<\/td>\n<td style=\"text-align: right;\">1535 nm<\/td>\n<td style=\"text-align: right;\">40 \u00b5J<\/td>\n<td style=\"text-align: right;\">1000 Hz<\/td>\n<td style=\"text-align: right;\">3\u20136 ns<\/td>\n<td style=\"text-align: right;\">\u226415 mrad<\/td>\n<td style=\"text-align: right;\">&lt;2 V<\/td>\n<td style=\"text-align: right;\">\u221240 a +65 \u00b0C<\/td>\n<td style=\"text-align: right;\">Confirmar por configuraci\u00f3n<\/td>\n<\/tr>\n<tr>\n<td>1535-LXER100<\/td>\n<td style=\"text-align: right;\">1535 nm<\/td>\n<td style=\"text-align: right;\">100 \u00b5J<\/td>\n<td style=\"text-align: right;\">1\u201310 Hz<\/td>\n<td style=\"text-align: right;\">3\u20136 ns<\/td>\n<td style=\"text-align: right;\">\u226410 mrad<\/td>\n<td style=\"text-align: right;\">&lt;2 V<\/td>\n<td style=\"text-align: right;\">\u221240 a +65 \u00b0C<\/td>\n<td style=\"text-align: right;\">9 g<\/td>\n<\/tr>\n<tr>\n<td>1535-LXER200<\/td>\n<td style=\"text-align: right;\">1535 nm<\/td>\n<td style=\"text-align: right;\">200 \u00b5J<\/td>\n<td style=\"text-align: right;\">1\u201310 Hz<\/td>\n<td style=\"text-align: right;\">3\u20136 ns<\/td>\n<td style=\"text-align: right;\">\u226410 mrad<\/td>\n<td style=\"text-align: right;\">&lt;2 V<\/td>\n<td style=\"text-align: right;\">\u221240 a +65 \u00b0C<\/td>\n<td style=\"text-align: right;\">9 g<\/td>\n<\/tr>\n<tr>\n<td>1535-LXER300<\/td>\n<td style=\"text-align: right;\">1535 nm<\/td>\n<td style=\"text-align: right;\">300 \u00b5J<\/td>\n<td style=\"text-align: right;\">1\u201310 Hz<\/td>\n<td style=\"text-align: right;\">3\u20136 ns<\/td>\n<td style=\"text-align: right;\">\u226410 mrad<\/td>\n<td style=\"text-align: right;\">&lt;2 V<\/td>\n<td style=\"text-align: right;\">\u221240 a +65 \u00b0C<\/td>\n<td style=\"text-align: right;\">9 g<\/td>\n<\/tr>\n<tr>\n<td>1535-LXER400<\/td>\n<td style=\"text-align: right;\">1535 nm<\/td>\n<td style=\"text-align: right;\">400 \u00b5J<\/td>\n<td style=\"text-align: right;\">1\u201310 Hz<\/td>\n<td style=\"text-align: right;\">3\u20136 ns<\/td>\n<td style=\"text-align: right;\">\u226415 mrad<\/td>\n<td style=\"text-align: right;\">&lt;2 V<\/td>\n<td style=\"text-align: right;\">\u221240 a +65 \u00b0C<\/td>\n<td style=\"text-align: right;\">11 g<\/td>\n<\/tr>\n<tr>\n<td>1535-LXER500<\/td>\n<td style=\"text-align: right;\">1535 nm<\/td>\n<td style=\"text-align: right;\">500 \u00b5J<\/td>\n<td style=\"text-align: right;\">1\u201310 Hz<\/td>\n<td style=\"text-align: right;\">3\u20136 ns<\/td>\n<td style=\"text-align: right;\">\u226415 mrad<\/td>\n<td style=\"text-align: right;\">&lt;2 V<\/td>\n<td style=\"text-align: right;\">\u221240 a +65 \u00b0C<\/td>\n<td style=\"text-align: right;\">13 g<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/figure>\n\n<h3 class=\"wp-block-heading\" style=\"margin-top:34px;margin-bottom:16px;font-size:clamp(21px,2.4vw,28px);font-weight:650;line-height:1.25\">L\u00f3gica de selecci\u00f3n pr\u00e1ctica<\/h3>\n\n<p class=\"wp-block-paragraph\"><strong>Comience con 1535-LXER040<\/strong> cuando la aplicaci\u00f3n valora una alta tasa de repetici\u00f3n de la fuente y el sistema puede cerrar su presupuesto de alcance con pulsos de 40 \u00b5J. A 1000 Hz, esta plataforma es adecuada para arquitecturas de muestreo de mayor tasa, experimentos de escaneo o sistemas que necesitan oportunidades m\u00e1s frecuentes para adquirir un retorno.<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>Comience con 1535-LXER100, 200 o 300<\/strong> cuando el instrumento necesita m\u00e1s energ\u00eda por pulso a una baja tasa de medici\u00f3n. Estas tres opciones comparten una clase de tasa de 1\u201310 Hz, ancho de pulso de 3\u20136 ns, divergencia de fuente \u226410 mrad y una masa listada de 9 g, lo que hace que la energ\u00eda del pulso sea el primer diferenciador dentro de este grupo.<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>Considere 1535-LXER400 o 500<\/strong> cuando el presupuesto del enlace necesita una clase de energ\u00eda transmitida m\u00e1s alta y el paquete puede aceptar la fuente correspondiente de 11 g o 13 g. Una mayor energ\u00eda puede agregar margen de retorno, pero no garantiza una distancia espec\u00edfica. La \u00f3ptica de transmisi\u00f3n, el llenado del objetivo, la atm\u00f3sfera, la apertura del receptor, el rendimiento del detector, el fondo y la l\u00f3gica de detecci\u00f3n siguen siendo parte del resultado.<\/p>\n\n<h3 class=\"wp-block-heading\" style=\"margin-top:34px;margin-bottom:16px;font-size:clamp(21px,2.4vw,28px);font-weight:650;line-height:1.25\">No seleccione solo por la energ\u00eda del pulso<\/h3>\n\n<p class=\"wp-block-paragraph\">Dos fuentes pueden tener puntos de operaci\u00f3n previstos muy diferentes incluso cuando ambas son adecuadas para la medici\u00f3n de alcance. La plataforma de 40 \u00b5J proporciona una tasa de pulso mucho m\u00e1s alta; la plataforma de 500 \u00b5J proporciona m\u00e1s energ\u00eda en cada pulso pero a una tasa de repetici\u00f3n m\u00e1s baja. Esas elecciones afectan la oportunidad de muestreo, la se\u00f1al m\u00e1xima, la potencia \u00f3ptica promedio, el comportamiento del excitador, el dise\u00f1o t\u00e9rmico, la recuperaci\u00f3n del detector y la validaci\u00f3n a nivel del sistema.<\/p>\n\n<div class=\"wp-block-group alignwide lumexis-visual-card has-border-color has-background is-layout-constrained wp-block-group-is-layout-constrained\" style=\"border-color:#dedede;border-width:1px;border-radius:2px;background-color:#ffffff;margin-top:34px;margin-bottom:34px\">\n<div class=\"wp-block-columns are-vertically-aligned-stretch is-layout-flex wp-container-core-columns-is-layout-946c1612 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-stretch is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:58%\">\n<div class=\"wp-block-group is-layout-constrained wp-container-core-group-is-layout-b2c065c3 wp-block-group-is-layout-constrained\" style=\"padding-top:clamp(28px,4vw,48px);padding-right:clamp(24px,4vw,48px);padding-bottom:clamp(28px,4vw,48px);padding-left:clamp(24px,4vw,48px)\">\n<p class=\"has-text-color wp-block-paragraph\" style=\"color:#a17d2f;margin-bottom:12px;font-size:11px;font-weight:700;letter-spacing:0.12em;text-transform:uppercase\">Interacci\u00f3n de par\u00e1metros<\/p>\n\n<h3 class=\"wp-block-heading\" style=\"margin-top:0;margin-bottom:14px;font-size:clamp(22px,2.4vw,30px);font-weight:650;line-height:1.2\">Eval\u00fae par\u00e1metros acoplados en el punto de operaci\u00f3n<\/h3>\n\n<p class=\"has-text-color wp-block-paragraph\" style=\"color:#4c5157;margin-bottom:0;font-size:14px;line-height:1.7\">Comparaci\u00f3n de una fuente de 40 \u00b5J, 1000 Hz y una fuente de 500 \u00b5J, 10 Hz, que ilustra las compensaciones entre tasa de repetici\u00f3n y energ\u00eda del pulso.<\/p>\n<\/div>\n<\/div>\n\n<div class=\"wp-block-column is-vertically-aligned-stretch is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:42%\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" src=\"https:\/\/lumexislaser.com\/wp-content\/uploads\/2026\/08\/pulse-energy-repetition-rate-tradeoff.webp\" alt=\"Comparaci\u00f3n de una fuente de 40 \u00b5J, 1000 Hz y una fuente de 500 \u00b5J, 10 Hz, que ilustra las compensaciones entre tasa de repetici\u00f3n y energ\u00eda del pulso.\"\/><\/figure>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"wp-block-group alignfull has-background is-layout-constrained wp-container-core-group-is-layout-c12f9e37 wp-block-group-is-layout-constrained\" style=\"background-color:#f5f5f3;margin-top:0;margin-bottom:0;padding-top:72px;padding-right:24px;padding-bottom:72px;padding-left:24px\">\n<h2 class=\"wp-block-heading\" style=\"margin-top:0;margin-bottom:32px;font-size:clamp(30px,4vw,44px);font-weight:700;line-height:1.08\">D\u00f3nde encaja la fuente en un tel\u00e9metro de tiempo de vuelo<\/h2>\n\n<div class=\"wp-block-group alignwide lumexis-visual-card has-border-color has-background is-layout-constrained wp-block-group-is-layout-constrained\" style=\"border-color:#dedede;border-width:1px;border-radius:2px;background-color:#ffffff;margin-top:34px;margin-bottom:34px\">\n<div class=\"wp-block-columns are-vertically-aligned-stretch is-layout-flex wp-container-core-columns-is-layout-946c1612 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-stretch is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:58%\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" src=\"https:\/\/lumexislaser.com\/wp-content\/uploads\/2026\/08\/time-of-flight-rangefinder-architecture.webp\" alt=\"Arquitectura del sistema desde una fuente l\u00e1ser de 1535 nm a trav\u00e9s de la \u00f3ptica de transmisi\u00f3n, el objetivo, la \u00f3ptica de recepci\u00f3n, el detector InGaAs y la electr\u00f3nica de temporizaci\u00f3n.\"\/><\/figure>\n<\/div>\n\n<div class=\"wp-block-column is-vertically-aligned-stretch is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:42%\">\n<div class=\"wp-block-group is-layout-constrained wp-container-core-group-is-layout-b2c065c3 wp-block-group-is-layout-constrained\" style=\"padding-top:clamp(28px,4vw,48px);padding-right:clamp(24px,4vw,48px);padding-bottom:clamp(28px,4vw,48px);padding-left:clamp(24px,4vw,48px)\">\n<p class=\"has-text-color wp-block-paragraph\" style=\"color:#a17d2f;margin-bottom:12px;font-size:11px;font-weight:700;letter-spacing:0.12em;text-transform:uppercase\">Arquitectura del sistema<\/p>\n\n<h3 class=\"wp-block-heading\" style=\"margin-top:0;margin-bottom:14px;font-size:clamp(22px,2.4vw,30px);font-weight:650;line-height:1.2\">Revise la cadena \u00f3ptica y de medici\u00f3n completa<\/h3>\n\n<p class=\"has-text-color wp-block-paragraph\" style=\"color:#4c5157;margin-bottom:0;font-size:14px;line-height:1.7\">Arquitectura del sistema desde una fuente l\u00e1ser de 1535 nm a trav\u00e9s de la \u00f3ptica de transmisi\u00f3n, el objetivo, la \u00f3ptica de recepci\u00f3n, el detector InGaAs y la electr\u00f3nica de temporizaci\u00f3n.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<p class=\"wp-block-paragraph\">Un instrumento de ToF directo mide el intervalo entre un pulso emitido y un retorno detectado. En la forma m\u00e1s simple, la distancia de un solo sentido es:<\/p>\n\n<div class=\"wp-block-group lumexis-formula-card has-background is-layout-constrained wp-container-core-group-is-layout-44c97188 wp-block-group-is-layout-constrained\" style=\"border-left-color:#c9a24b;border-left-width:3px;background-color:#f7f8fa;margin-top:24px;margin-bottom:24px;padding-top:22px;padding-right:26px;padding-bottom:22px;padding-left:26px\">\n<p class=\"has-text-align-center wp-block-paragraph\" style=\"font-size:24px\"><em>R<\/em> = <em>c<\/em>\u0394<em>t<\/em> \/ 2<\/p>\n<\/div>\n\n<p class=\"wp-block-paragraph\">donde <em>R<\/em> es la distancia de un solo sentido, <em>c<\/em> es la velocidad de propagaci\u00f3n de la luz, y <em>\u0394 t<\/em> es el intervalo de ida y vuelta medido. El factor de dos tiene en cuenta las trayectorias de salida y retorno. La explicaci\u00f3n de altimetr\u00eda l\u00e1ser de la NASA aplica la misma relaci\u00f3n de ida y vuelta: la distancia de viaje \u00f3ptico se calcula a partir de la velocidad de la luz y el tiempo transcurrido, y luego se divide por dos para el alcance de un solo sentido.<sup id=\"fnref:nasa-tof\"><a class=\"footnote-ref\" href=\"#fn:nasa-tof\">1<\/a><\/sup><\/p>\n\n<p class=\"wp-block-paragraph\">La fuente participa en tres eventos de temporizaci\u00f3n:<\/p>\n\n<ol class=\"wp-block-list\">\n<li><strong>Comando o disparo:<\/strong> la electr\u00f3nica de excitaci\u00f3n inicia un ciclo de pulso.<\/li>\n<li><strong>Emisi\u00f3n \u00f3ptica:<\/strong> el pulso realmente sale de la fuente. Este evento puede no ser id\u00e9ntico al borde del comando porque los retrasos del excitador y de acumulaci\u00f3n pueden variar.<\/li>\n<li><strong>Detecci\u00f3n de retorno:<\/strong> el receptor identifica un retorno del objetivo y genera un evento de temporizaci\u00f3n.<\/li>\n<\/ol>\n\n<p class=\"wp-block-paragraph\">Para una temporizaci\u00f3n de precisi\u00f3n, defina qu\u00e9 inicia el reloj. Un borde de comando es conveniente, pero un monitor de emisi\u00f3n o un retraso de emisi\u00f3n caracterizado puede proporcionar una mejor referencia. El enfoque correcto depende de la incertidumbre de alcance requerida, el dise\u00f1o del excitador, el comportamiento de temperatura, el modo de repetici\u00f3n y la estrategia de calibraci\u00f3n.<\/p>\n\n<h3 class=\"wp-block-heading\" style=\"margin-top:34px;margin-bottom:16px;font-size:clamp(21px,2.4vw,28px);font-weight:650;line-height:1.25\">El receptor debe coincidir con la longitud de onda y el pulso<\/h3>\n\n<p class=\"wp-block-paragraph\">A 1535 nm, el receptor com\u00fanmente usa un detector InGaAs en lugar de un detector de silicio. Los fotodiodos de avalancha InGaAs comerciales est\u00e1n disponibles con sensibilidad que cubre la regi\u00f3n de 1.5 \u00b5m y se promocionan espec\u00edficamente para aplicaciones de medici\u00f3n de distancia y receptor LiDAR.<sup id=\"fnref:hamamatsu\"><a class=\"footnote-ref\" href=\"#fn:hamamatsu\">2<\/a><\/sup><\/p>\n\n<p class=\"wp-block-paragraph\">La elecci\u00f3n del detector no es solo una decisi\u00f3n de longitud de onda. El equipo de ingenier\u00eda tambi\u00e9n debe definir:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>\u00e1rea activa y campo de visi\u00f3n \u00f3ptico;<\/li>\n<li>responsividad o eficiencia de detecci\u00f3n en la longitud de onda de operaci\u00f3n;<\/li>\n<li>ganancia, ancho de banda, ruido y comportamiento de temperatura;<\/li>\n<li>saturaci\u00f3n y recuperaci\u00f3n despu\u00e9s de retornos cercanos fuertes;<\/li>\n<li>filtrado de luz de fondo;<\/li>\n<li>umbral, fracci\u00f3n constante, correlaci\u00f3n u otro m\u00e9todo de temporizaci\u00f3n;<\/li>\n<li>Criterios de falsa alarma y detecci\u00f3n v\u00e1lida.<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Un pulso \u00f3ptico m\u00e1s fuerte puede ayudar a la se\u00f1al de retorno, pero tambi\u00e9n puede hacer que los objetivos cercanos, las reflexiones internas y la recuperaci\u00f3n del receptor sean m\u00e1s exigentes. El transmisor y el receptor deben, por lo tanto, revisarse juntos.<\/p>\n<\/div>\n\n<div class=\"wp-block-group alignfull has-background is-layout-constrained wp-container-core-group-is-layout-c12f9e37 wp-block-group-is-layout-constrained\" style=\"background-color:#ffffff;margin-top:0;margin-bottom:0;padding-top:72px;padding-right:24px;padding-bottom:72px;padding-left:24px\">\n<h2 class=\"wp-block-heading\" style=\"margin-top:0;margin-bottom:32px;font-size:clamp(30px,4vw,44px);font-weight:700;line-height:1.08\">C\u00f3mo leer los par\u00e1metros de la fuente<\/h2>\n\n<h3 class=\"wp-block-heading\" style=\"margin-top:34px;margin-bottom:16px;font-size:clamp(21px,2.4vw,28px);font-weight:650;line-height:1.25\">Energ\u00eda de pulso: energ\u00eda \u00fatil entregada en un evento<\/h3>\n\n<p class=\"wp-block-paragraph\">Energ\u00eda de pulso <em>E_p<\/em>, expresada en microjulios, es la energ\u00eda \u00f3ptica en un solo pulso. En un sistema sin otros cambios, m\u00e1s energ\u00eda transmitida puede aumentar la energ\u00eda disponible para el retorno de un objetivo. En un instrumento real, \u201csin otros cambios\u201d rara vez se cumple: el empaque, las condiciones de excitaci\u00f3n, la tasa de repetici\u00f3n, la divergencia, la \u00f3ptica, el rango din\u00e1mico del detector y la vida \u00fatil tambi\u00e9n pueden cambiar.<\/p>\n\n<p class=\"wp-block-paragraph\">La energ\u00eda de pulso no es una clasificaci\u00f3n de distancia. El receptor solo ve una peque\u00f1a fracci\u00f3n del pulso emitido despu\u00e9s de la dispersi\u00f3n del haz, la interacci\u00f3n con el objetivo, la p\u00e9rdida atmosf\u00e9rica, la p\u00e9rdida de recolecci\u00f3n, el filtrado y la conversi\u00f3n del detector.<\/p>\n\n<h3 class=\"wp-block-heading\" style=\"margin-top:34px;margin-bottom:16px;font-size:clamp(21px,2.4vw,28px);font-weight:650;line-height:1.25\">Ancho de pulso: una entrada de temporizaci\u00f3n a escala de nanosegundos<\/h3>\n\n<p class=\"wp-block-paragraph\">Las plataformas de fuente Lumexis Er:glass enumeran un rango de ancho de pulso de 3\u20136 ns. Los pulsos cortos apoyan la temporizaci\u00f3n directa de vuelo porque la forma de onda de retorno puede localizarse en el tiempo, pero el ancho de pulso es solo un contribuyente a la precisi\u00f3n de la distancia. El ancho de banda del detector, la relaci\u00f3n se\u00f1al-ruido, el umbral de temporizaci\u00f3n, la forma del pulso, la profundidad del objetivo, el m\u00e9todo de muestreo y la calibraci\u00f3n pueden ensanchar o desplazar el evento medido.<\/p>\n\n<p class=\"wp-block-paragraph\">La longitud espacial aproximada de un pulso en espacio libre es <em>c\u03c4<\/em>, pero el intervalo de alcance unidireccional correspondiente a una duraci\u00f3n de ida y vuelta es <em>c\u03c4\/2<\/em>. Eso <strong>no<\/strong> significa que un pulso de 6 ns produce autom\u00e1ticamente una precisi\u00f3n fija de <em>c\u03c4\/2<\/em>. La electr\u00f3nica de estimaci\u00f3n puede localizar un evento dentro de una forma de onda, mientras que el ruido y la estructura del objetivo pueden mover el punto de temporizaci\u00f3n aparente. Use la precisi\u00f3n y repetibilidad medidas del sistema\u2014no solo el ancho de pulso\u2014para la aceptaci\u00f3n.<\/p>\n\n<h3 class=\"wp-block-heading\" style=\"margin-top:34px;margin-bottom:16px;font-size:clamp(21px,2.4vw,28px);font-weight:650;line-height:1.25\">Potencia m\u00e1xima: una estimaci\u00f3n que requiere una suposici\u00f3n de forma de pulso<\/h3>\n\n<p class=\"wp-block-paragraph\">Para una aproximaci\u00f3n de pulso rectangular:<\/p>\n\n<div class=\"wp-block-group lumexis-formula-card has-background is-layout-constrained wp-container-core-group-is-layout-44c97188 wp-block-group-is-layout-constrained\" style=\"border-left-color:#c9a24b;border-left-width:3px;background-color:#f7f8fa;margin-top:24px;margin-bottom:24px;padding-top:22px;padding-right:26px;padding-bottom:22px;padding-left:26px\">\n<p class=\"has-text-align-center wp-block-paragraph\" style=\"font-size:24px\"><em>P<\/em><sub>pico<\/sub> \u2248 <em>E<\/em><sub>p<\/sub> \/ \u03c4<sub>p<\/sub><\/p>\n<\/div>\n\n<p class=\"wp-block-paragraph\">Un pulso nominal de 100 \u00b5J en 3\u20136 ns corresponde a una potencia promedio durante ese intervalo de pulso idealizado de aproximadamente 17\u201333 kW. Un pulso nominal de 500 \u00b5J da aproximadamente 83\u2013167 kW con la misma aritm\u00e9tica. Estas son estimaciones explicativas, no valores de producto garantizados: la potencia m\u00e1xima real depende de la forma temporal medida del pulso y de la definici\u00f3n utilizada para el ancho de pulso.<\/p>\n\n<p class=\"wp-block-paragraph\">La potencia m\u00e1xima es importante para la formaci\u00f3n de la se\u00f1al de retorno y la revisi\u00f3n de componentes \u00f3pticos. No es lo mismo que la potencia \u00f3ptica promedio, la potencia de entrada el\u00e9ctrica o la demanda m\u00e1xima de la fuente de alimentaci\u00f3n del anfitri\u00f3n.<\/p>\n\n<h3 class=\"wp-block-heading\" style=\"margin-top:34px;margin-bottom:16px;font-size:clamp(21px,2.4vw,28px);font-weight:650;line-height:1.25\">Tasa de repetici\u00f3n: oportunidad de medici\u00f3n, no tasa de salida garantizada<\/h3>\n\n<p class=\"wp-block-paragraph\">La tasa de repetici\u00f3n describe con qu\u00e9 frecuencia la fuente puede emitir bajo el modo de operaci\u00f3n especificado. Una tasa de pulso \u00f3ptico de 1000 Hz puede soportar un muestreo frecuente, pero el instrumento terminado puede generar menos rangos v\u00e1lidos debido a la compuerta del receptor, la p\u00e9rdida de objetivo, el procesamiento, el filtrado, la comunicaci\u00f3n o la geometr\u00eda de escaneo. Del mismo modo, una fuente de 10 Hz no garantiza diez valores de distancia aceptados por segundo.<\/p>\n\n<p class=\"wp-block-paragraph\">Defina cuatro tasas separadas en la especificaci\u00f3n del sistema:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>tasa de disparo comandada;<\/li>\n<li>tasa de emisi\u00f3n \u00f3ptica confirmada;<\/li>\n<li>tasa de adquisici\u00f3n del receptor;<\/li>\n<li>tasa de salida de rango v\u00e1lido.<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Mantener estos t\u00e9rminos separados previene un error de integraci\u00f3n com\u00fan: tratar un n\u00famero de repetici\u00f3n de la fuente como la tasa de datos garantizada del instrumento completo.<\/p>\n\n<h3 class=\"wp-block-heading\" style=\"margin-top:34px;margin-bottom:16px;font-size:clamp(21px,2.4vw,28px);font-weight:650;line-height:1.25\">Potencia \u00f3ptica promedio: energ\u00eda de pulso multiplicada por la tasa<\/h3>\n\n<p class=\"wp-block-paragraph\">Para una fuente pulsada repetitiva:<\/p>\n\n<div class=\"wp-block-group lumexis-formula-card has-background is-layout-constrained wp-container-core-group-is-layout-44c97188 wp-block-group-is-layout-constrained\" style=\"border-left-color:#c9a24b;border-left-width:3px;background-color:#f7f8fa;margin-top:24px;margin-bottom:24px;padding-top:22px;padding-right:26px;padding-bottom:22px;padding-left:26px\">\n<p class=\"has-text-align-center wp-block-paragraph\" style=\"font-size:24px\"><em>P<\/em><sub>avg<\/sub> = <em>E<\/em><sub>p<\/sub><em>f<\/em><sub>rep<\/sub><\/p>\n<\/div>\n\n<p class=\"wp-block-paragraph\">Esta relaci\u00f3n explica por qu\u00e9 una fuente de menor energ\u00eda y alta tasa puede tener m\u00e1s salida \u00f3ptica promedio que una fuente de mayor energ\u00eda y baja tasa. No proporciona la eficiencia el\u00e9ctrica de la fuente ni la corriente m\u00e1xima requerida de su controlador. Pregunte por separado sobre la entrada del controlador, el comportamiento de la corriente de pulso, el ciclo de trabajo, la secuencia de arranque y la ruta t\u00e9rmica.<\/p>\n\n<h3 class=\"wp-block-heading\" style=\"margin-top:34px;margin-bottom:16px;font-size:clamp(21px,2.4vw,28px);font-weight:650;line-height:1.25\">Divergencia de la fuente: una entrada a la \u00f3ptica de transmisi\u00f3n<\/h3>\n\n<p class=\"wp-block-paragraph\">El valor listado de \u226410 o \u226415 mrad describe la salida de la fuente, no necesariamente el haz final que sale del instrumento. Un tel\u00e9metro completo normalmente a\u00f1ade \u00f3ptica de colimaci\u00f3n o expansi\u00f3n de haz para establecer el di\u00e1metro de salida, la divergencia, el frente de onda y el eje \u00f3ptico.<\/p>\n\n<div class=\"wp-block-group alignwide lumexis-visual-card has-border-color has-background is-layout-constrained wp-block-group-is-layout-constrained\" style=\"border-color:#dedede;border-width:1px;border-radius:2px;background-color:#ffffff;margin-top:34px;margin-bottom:34px\">\n<div class=\"wp-block-columns are-vertically-aligned-stretch is-layout-flex wp-container-core-columns-is-layout-946c1612 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-stretch is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:58%\">\n<div class=\"wp-block-group is-layout-constrained wp-container-core-group-is-layout-b2c065c3 wp-block-group-is-layout-constrained\" style=\"padding-top:clamp(28px,4vw,48px);padding-right:clamp(24px,4vw,48px);padding-bottom:clamp(28px,4vw,48px);padding-left:clamp(24px,4vw,48px)\">\n<p class=\"has-text-color wp-block-paragraph\" style=\"color:#a17d2f;margin-bottom:12px;font-size:11px;font-weight:700;letter-spacing:0.12em;text-transform:uppercase\">Entrega \u00f3ptica<\/p>\n\n<h3 class=\"wp-block-heading\" style=\"margin-top:0;margin-bottom:14px;font-size:clamp(22px,2.4vw,30px);font-weight:650;line-height:1.2\">Equilibre la potencia, la entrega del haz y la geometr\u00eda del objetivo<\/h3>\n\n<p class=\"has-text-color wp-block-paragraph\" style=\"color:#4c5157;margin-bottom:0;font-size:14px;line-height:1.7\">Diagrama de integraci\u00f3n \u00f3ptica que muestra la divergencia de fuente bruta de 10\u201315 mrad, la \u00f3ptica de colimaci\u00f3n y el haz de transmisi\u00f3n final del sistema.<\/p>\n<\/div>\n<\/div>\n\n<div class=\"wp-block-column is-vertically-aligned-stretch is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:42%\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" src=\"https:\/\/lumexislaser.com\/wp-content\/uploads\/2026\/08\/source-divergence-collimation.webp\" alt=\"Diagrama de integraci\u00f3n \u00f3ptica que muestra la divergencia de fuente bruta de 10\u201315 mrad, la \u00f3ptica de colimaci\u00f3n y el haz de transmisi\u00f3n final del sistema.\"\/><\/figure>\n<\/div>\n<\/div>\n<\/div>\n\n<p class=\"wp-block-paragraph\">Para una estimaci\u00f3n de campo lejano usando divergencia de \u00e1ngulo completo:<\/p>\n\n<div class=\"wp-block-group lumexis-formula-card has-background is-layout-constrained wp-container-core-group-is-layout-44c97188 wp-block-group-is-layout-constrained\" style=\"border-left-color:#c9a24b;border-left-width:3px;background-color:#f7f8fa;margin-top:24px;margin-bottom:24px;padding-top:22px;padding-right:26px;padding-bottom:22px;padding-left:26px\">\n<p class=\"has-text-align-center wp-block-paragraph\" style=\"font-size:24px\"><em>d<\/em> \u2248 <em>R<\/em>\u03b8<\/p>\n<\/div>\n\n<p class=\"wp-block-paragraph\">donde <em>d<\/em> es el di\u00e1metro aproximado del haz en el objetivo, <em>R<\/em> es la distancia, y <em>\u03b8<\/em> es la divergencia de \u00e1ngulo completo en radianes. Esta relaci\u00f3n simple es \u00fatil para el pensamiento de llenado del objetivo, pero el di\u00e1metro inicial del haz, el perfil del haz, el enfoque, la aberraci\u00f3n, la turbulencia y el movimiento de apuntado tambi\u00e9n pueden importar.<\/p>\n\n<p class=\"wp-block-paragraph\">Un haz final m\u00e1s estrecho puede colocar m\u00e1s energ\u00eda en un objetivo peque\u00f1o y distante. Tambi\u00e9n requiere un control m\u00e1s estricto de la l\u00ednea de mira, el apuntado, la vibraci\u00f3n y la deriva t\u00e9rmica. El eje de transmisi\u00f3n debe permanecer dentro del campo de visi\u00f3n del receptor y sobre el objetivo previsto durante toda la operaci\u00f3n.<\/p>\n<\/div>\n\n<div class=\"wp-block-group alignfull has-background is-layout-constrained wp-container-core-group-is-layout-c12f9e37 wp-block-group-is-layout-constrained\" style=\"background-color:#f5f5f3;margin-top:0;margin-bottom:0;padding-top:72px;padding-right:24px;padding-bottom:72px;padding-left:24px\">\n<h2 class=\"wp-block-heading\" style=\"margin-top:0;margin-bottom:32px;font-size:clamp(30px,4vw,44px);font-weight:700;line-height:1.08\">Por qu\u00e9 la longitud de onda sola no determina el rendimiento del sistema<\/h2>\n\n<p class=\"wp-block-paragraph\">La banda de 1535 nm es \u00fatil para fuentes pulsadas compactas de Er:glass y es compatible con la tecnolog\u00eda de receptores InGaAs establecida. Tambi\u00e9n soporta un espacio de dise\u00f1o de seguridad l\u00e1ser diferente de las longitudes de onda m\u00e1s cortas del infrarrojo cercano porque la absorci\u00f3n del tejido y los l\u00edmites de exposici\u00f3n aplicables var\u00edan con la longitud de onda.<\/p>\n\n<p class=\"wp-block-paragraph\">Sin embargo, ninguna etiqueta de longitud de onda establece la clasificaci\u00f3n de un producto terminado. La clasificaci\u00f3n depende de la emisi\u00f3n accesible, la energ\u00eda de pulso, la duraci\u00f3n del pulso, el patr\u00f3n de repetici\u00f3n, la apertura, la divergencia, la geometr\u00eda de exposici\u00f3n, el m\u00e9todo de medici\u00f3n y el ensamblaje \u00f3ptico completado. Lumexis definir\u00e1 cualquier clasificaci\u00f3n formal o declaraci\u00f3n de cumplimiento solo para una configuraci\u00f3n final documentada.<\/p>\n\n<p class=\"wp-block-paragraph\">La longitud de onda tampoco elimina los l\u00edmites ambientales. Niebla, lluvia, polvo, aerosoles, centelleo de calor, condensaci\u00f3n y una ventana externa sucia pueden reducir el retorno utilizable o crear retrodispersi\u00f3n cercana no deseada. Pruebe el transmisor y receptor ensamblados a trav\u00e9s de la ventana final en condiciones representativas.<\/p>\n<\/div>\n\n<div class=\"wp-block-group alignfull has-background is-layout-constrained wp-container-core-group-is-layout-c12f9e37 wp-block-group-is-layout-constrained\" style=\"background-color:#ffffff;margin-top:0;margin-bottom:0;padding-top:72px;padding-right:24px;padding-bottom:72px;padding-left:24px\">\n<h2 class=\"wp-block-heading\" style=\"margin-top:0;margin-bottom:32px;font-size:clamp(30px,4vw,44px);font-weight:700;line-height:1.08\">El presupuesto de alcance: traduzca la aplicaci\u00f3n en requisitos de fuente<\/h2>\n\n<p class=\"wp-block-paragraph\">Para un objetivo difuso, una relaci\u00f3n direccional simplificada puede escribirse como:<\/p>\n\n<div class=\"wp-block-group lumexis-formula-card has-background is-layout-constrained wp-container-core-group-is-layout-44c97188 wp-block-group-is-layout-constrained\" style=\"border-left-color:#c9a24b;border-left-width:3px;background-color:#f7f8fa;margin-top:24px;margin-bottom:24px;padding-top:22px;padding-right:26px;padding-bottom:22px;padding-left:26px\">\n<p class=\"has-text-align-center wp-block-paragraph\" style=\"font-size:24px\"><em>p<\/em><sub>superficie<\/sub> = <em>p<\/em><sub>sensor<\/sub> + <em>R<\/em><strong>u<\/strong><sub>observaci\u00f3n<\/sub><\/p>\n<\/div>\n\n<p class=\"wp-block-paragraph\">donde:<\/p>\n\n<ul class=\"wp-block-list\">\n<li><em>E_r<\/em> es la energ\u00eda de pulso recibida;<\/li>\n<li><em>E_t<\/em> es energ\u00eda de pulso transmitida;<\/li>\n<li>\u03b7<sub>tx<\/sub><em> y <\/em>\u03b7<sub>rx<\/sub> representan la eficiencia de la trayectoria de transmisi\u00f3n y recepci\u00f3n;<\/li>\n<li><em>T^2<\/em> representa la transmisi\u00f3n atmosf\u00e9rica bidireccional;<\/li>\n<li>F<sub>objetivo<\/sub> representa la fracci\u00f3n \u00fatil de la huella del haz sobre el objetivo;<\/li>\n<li><em>\u03c1<\/em> es un t\u00e9rmino efectivo de retorno del objetivo para el modelo elegido;<\/li>\n<li><em>A_r<\/em> es el \u00e1rea de apertura del receptor;<\/li>\n<li><em>R<\/em> es el alcance.<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Esta es una relaci\u00f3n proporcional educativa, no una ecuaci\u00f3n de aceptaci\u00f3n universal. Los modelos exactos de enlace dependen de si el objetivo llena el haz, la geometr\u00eda y dispersi\u00f3n del objetivo, el perfil del haz, el campo de visi\u00f3n del receptor, el fondo, las estad\u00edsticas de detecci\u00f3n y la arquitectura del sistema. El an\u00e1lisis publicado de energ\u00eda de retorno de ICESat\/GLAS vincula igualmente la energ\u00eda de pulso transmitida, el \u00e1rea del receptor, el alcance, la respuesta de la superficie y la transmisi\u00f3n atmosf\u00e9rica bidireccional.<sup id=\"fnref:glas-link\"><a class=\"footnote-ref\" href=\"#fn:glas-link\">3<\/a><\/sup><\/p>\n\n<h3 class=\"wp-block-heading\" style=\"margin-top:34px;margin-bottom:16px;font-size:clamp(21px,2.4vw,28px);font-weight:650;line-height:1.25\">Ocho preguntas de presupuesto de alcance que mejoran una recomendaci\u00f3n de fuente<\/h3>\n\n<h4>\u00bfCu\u00e1l es el objetivo?<\/h4>\n\n<p class=\"wp-block-paragraph\">Proporcione dimensiones, material, acabado, color solo como contexto de apoyo, reflectividad esperada a la longitud de onda de operaci\u00f3n si se conoce, y el rango de \u00e1ngulos de incidencia. Una pared difusa grande y un borde estrecho no son objetivos equivalentes.<\/p>\n\n<h4>\u00bfLlena el objetivo la huella del haz?<\/h4>\n\n<p class=\"wp-block-paragraph\">Si la huella del haz sobrepasa el objetivo, solo parte de la energ\u00eda transmitida interact\u00faa de manera \u00fatil. Una fuente de mayor energ\u00eda puede no compensar eficientemente un apuntamiento deficiente o un haz final sobredimensionado.<\/p>\n\n<h4>\u00bfCu\u00e1l es el alcance normal, no solo el m\u00e1ximo?<\/h4>\n\n<p class=\"wp-block-paragraph\">La distancia de trabajo normal a menudo determina la mejor fuente. Un sistema dise\u00f1ado solo en torno a un m\u00e1ximo extremo puede crear una se\u00f1al de retorno cercano excesiva, tama\u00f1o innecesario, menor tasa, mayor costo o validaci\u00f3n m\u00e1s dif\u00edcil.<\/p>\n\n<h4>\u00bfQu\u00e9 atm\u00f3sfera y ventana son realistas?<\/h4>\n\n<p class=\"wp-block-paragraph\">Especifique visibilidad, humedad, polvo, lluvia, niebla, altitud de operaci\u00f3n, material de la ventana externa, recubrimientos, \u00e1ngulo de incidencia y plan de contaminaci\u00f3n. La p\u00e9rdida se aplica en las trayectorias de salida y retorno.<\/p>\n\n<h4>\u00bfQu\u00e9 apertura de recepci\u00f3n est\u00e1 disponible?<\/h4>\n\n<p class=\"wp-block-paragraph\">Para una apertura circular, el \u00e1rea de recolecci\u00f3n es <em>A_r=\u03c0 D^2\/4<\/em>. Aumentar el di\u00e1metro puede mejorar la recolecci\u00f3n, pero tambi\u00e9n afecta la envolvente, la masa, el tama\u00f1o de la ventana, el campo de visi\u00f3n, la alineaci\u00f3n y el costo.<\/p>\n\n<h4>\u00bfQu\u00e9 detector y umbral se utilizar\u00e1n?<\/h4>\n\n<p class=\"wp-block-paragraph\">El ruido del receptor y el fondo establecen cu\u00e1nto retorno se necesita para una probabilidad definida de detecci\u00f3n y un nivel de falsa alarma. \u201cDetectable\u201d debe estar conectado a un criterio de aceptaci\u00f3n.<\/p>\n\n<h4>\u00bfQu\u00e9 tan estable es la l\u00ednea de visi\u00f3n?<\/h4>\n\n<p class=\"wp-block-paragraph\">Incluya error de apuntamiento, vibraci\u00f3n, tolerancia mec\u00e1nica, deriva de boresight, desplazamiento del eje \u00f3ptico y cualquier error de alineaci\u00f3n del esc\u00e1ner o c\u00e1mara. Una divergencia m\u00e1s estrecha solo ayuda si el sistema ilumina consistentemente el objetivo previsto.<\/p>\n\n<h4>\u00bfQu\u00e9 comportamiento de medici\u00f3n v\u00e1lida se requiere?<\/h4>\n\n<p class=\"wp-block-paragraph\">Defina retornos perdidos, retornos falsos, escenas de m\u00faltiples superficies, l\u00f3gica de primer\/\u00faltimo\/retorno m\u00e1s fuerte, gating, timeout y reporte de datos inv\u00e1lidos. La fuente crea pulsos; el sistema de medici\u00f3n completo decide qu\u00e9 retorno se convierte en una distancia.<\/p>\n<\/div>\n\n<div class=\"wp-block-group alignfull has-background is-layout-constrained wp-container-core-group-is-layout-c12f9e37 wp-block-group-is-layout-constrained\" style=\"background-color:#f5f5f3;margin-top:0;margin-bottom:0;padding-top:72px;padding-right:24px;padding-bottom:72px;padding-left:24px\">\n<h2 class=\"wp-block-heading\" style=\"margin-top:0;margin-bottom:32px;font-size:clamp(30px,4vw,44px);font-weight:700;line-height:1.08\">Lista de verificaci\u00f3n de integraci\u00f3n para equipos de ingenier\u00eda OEM<\/h2>\n\n<h3 class=\"wp-block-heading\" style=\"margin-top:34px;margin-bottom:16px;font-size:clamp(21px,2.4vw,28px);font-weight:650;line-height:1.25\">Accionamiento el\u00e9ctrico y disparo<\/h3>\n\n<ul class=\"wp-block-list\">\n<li>Confirme la configuraci\u00f3n exacta de la fuente y el controlador compatible antes de aplicar energ\u00eda.<\/li>\n<li>Defina los l\u00edmites de suministro en los pines de la fuente bajo condiciones transitorias, no solo en la fuente de banco.<\/li>\n<li>Documente el nivel de disparo, flanco, duraci\u00f3n del pulso, tasa permitida, comportamiento de inhibici\u00f3n y secuencia de arranque.<\/li>\n<li>Separe la referencia de emisi\u00f3n \u00f3ptica del disparo de comando cuando el presupuesto de incertidumbre lo requiera.<\/li>\n<li>Revise la puesta a tierra, impedancia del cable, acoplamiento electromagn\u00e9tico y aislamiento del receptor en el gabinete completo.<\/li>\n<\/ul>\n\n<h3 class=\"wp-block-heading\" style=\"margin-top:34px;margin-bottom:16px;font-size:clamp(21px,2.4vw,28px);font-weight:650;line-height:1.25\">Montaje mec\u00e1nico<\/h3>\n\n<ul class=\"wp-block-list\">\n<li>Utilice el dato de montaje aprobado y los l\u00edmites de sujetadores del plano espec\u00edfico del pedido.<\/li>\n<li>Evite la tensi\u00f3n del chasis que pueda alterar la alineaci\u00f3n o da\u00f1ar el paquete de la fuente.<\/li>\n<li>Defina la ubicaci\u00f3n del eje \u00f3ptico y la tolerancia angular relativa al dato del host.<\/li>\n<li>Reserve autoridad de ajuste o calibraci\u00f3n si la pila de tolerancias de producci\u00f3n no puede mantener el boresight directamente.<\/li>\n<li>Verifique los requisitos de propiedades de masa y vibraci\u00f3n en el instrumento ensamblado.<\/li>\n<\/ul>\n\n<h3 class=\"wp-block-heading\" style=\"margin-top:34px;margin-bottom:16px;font-size:clamp(21px,2.4vw,28px);font-weight:650;line-height:1.25\">Tren \u00f3ptico<\/h3>\n\n<ul class=\"wp-block-list\">\n<li>Seleccione la distancia focal del colimador, apertura libre, recubrimiento y distancia de trabajo para la salida real de la fuente.<\/li>\n<li>Verifique el recorte del haz a trav\u00e9s de la tolerancia y la temperatura.<\/li>\n<li>Controle la retroalimentaci\u00f3n y las reflexiones internas de lentes, filtros y la ventana externa.<\/li>\n<li>Mantenga la fuga de transmisi\u00f3n fuera del receptor o defina la recuperaci\u00f3n y el gating en torno a ella.<\/li>\n<li>Mida la divergencia final y el alineamiento despu\u00e9s del ensamblaje de la carcasa, no solo en el banco \u00f3ptico.<\/li>\n<\/ul>\n\n<h3 class=\"wp-block-heading\" style=\"margin-top:34px;margin-bottom:16px;font-size:clamp(21px,2.4vw,28px);font-weight:650;line-height:1.25\">Dise\u00f1o t\u00e9rmico y ambiental<\/h3>\n\n<p class=\"wp-block-paragraph\">El rango de temperatura de operaci\u00f3n de la plataforma es de \u221240 a +65 \u00b0C, pero el rendimiento del sistema terminado a\u00fan depende del driver, el montaje, la carcasa, la \u00f3ptica, el detector y la calibraci\u00f3n. Una fuente que opera dentro de los l\u00edmites de temperatura no garantiza energ\u00eda de pulso, temporizaci\u00f3n, alineaci\u00f3n o alcance constantes para el instrumento completo.<\/p>\n\n<p class=\"wp-block-paragraph\">Estructure el plan de calificaci\u00f3n en torno a:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>arranque en fr\u00edo y arranque en caliente;<\/li>\n<li>energ\u00eda de pulso y retardo de emisi\u00f3n en funci\u00f3n de la temperatura;<\/li>\n<li>perfiles de servicio de alta y baja frecuencia;<\/li>\n<li>deriva del eje \u00f3ptico;<\/li>\n<li>condensaci\u00f3n y contaminaci\u00f3n de la ventana;<\/li>\n<li>vibraci\u00f3n antes y despu\u00e9s de la alineaci\u00f3n;<\/li>\n<li>ruido del receptor y umbral de detecci\u00f3n en funci\u00f3n de la temperatura;<\/li>\n<li>ciclado repetido y l\u00edmites de aceptaci\u00f3n.<\/li>\n<\/ul>\n\n<h3 class=\"wp-block-heading\" style=\"margin-top:34px;margin-bottom:16px;font-size:clamp(21px,2.4vw,28px);font-weight:650;line-height:1.25\">Producci\u00f3n y aceptaci\u00f3n<\/h3>\n\n<p class=\"wp-block-paragraph\">Convierta la intenci\u00f3n del sistema en mediciones que puedan repetirse:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>energ\u00eda de pulso y m\u00e9todo de medici\u00f3n;<\/li>\n<li>definici\u00f3n del ancho de pulso y ancho de banda del instrumento;<\/li>\n<li>longitud de onda central y m\u00e9todo espectral;<\/li>\n<li>modo de repetici\u00f3n y perfil de servicio;<\/li>\n<li>definici\u00f3n de divergencia de la fuente y plano de medici\u00f3n;<\/li>\n<li>dato de referencia del eje \u00f3ptico y error permitido;<\/li>\n<li>condiciones de prueba el\u00e9ctrica;<\/li>\n<li>estado ambiental y tiempo de estabilizaci\u00f3n;<\/li>\n<li>trazabilidad, plan de muestreo y l\u00edmites de aprobaci\u00f3n\/rechazo.<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Cuanto m\u00e1s precisamente se definan estos elementos antes del lanzamiento del prototipo, m\u00e1s f\u00e1cil ser\u00e1 comparar muestras, controlar cambios de integraci\u00f3n y escalar la producci\u00f3n.<\/p>\n<\/div>\n\n<div class=\"wp-block-group alignfull has-background is-layout-constrained wp-container-core-group-is-layout-c12f9e37 wp-block-group-is-layout-constrained\" style=\"background-color:#ffffff;margin-top:0;margin-bottom:0;padding-top:72px;padding-right:24px;padding-bottom:72px;padding-left:24px\">\n<h2 class=\"wp-block-heading\" style=\"margin-top:0;margin-bottom:32px;font-size:clamp(30px,4vw,44px);font-weight:700;line-height:1.08\">Qu\u00e9 incluir en su RFQ<\/h2>\n\n<figure class=\"wp-block-table alignwide is-style-stripes lumexis-solution-table\"><table>\n<thead>\n<tr>\n<th>Categor\u00eda<\/th>\n<th>Informaci\u00f3n a proporcionar<\/th>\n<th>Por qu\u00e9 Lumexis lo necesita<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Aplicaci\u00f3n<\/td>\n<td>medici\u00f3n de distancia compacta, medici\u00f3n asistida por c\u00e1mara, instrumento de campo, ToF cient\u00edfico o subsistema OEM<\/td>\n<td>establece el patr\u00f3n de operaci\u00f3n y el l\u00edmite de integraci\u00f3n<\/td>\n<\/tr>\n<tr>\n<td>Objetivo<\/td>\n<td>tama\u00f1o, material, comportamiento de retorno, \u00e1ngulo de incidencia, fondo<\/td>\n<td>determina el retorno \u00fatil y el desaf\u00edo de detecci\u00f3n<\/td>\n<\/tr>\n<tr>\n<td>Distancia<\/td>\n<td>m\u00ednimo, normal, m\u00e1ximo y margen requerido<\/td>\n<td>evita la selecci\u00f3n en torno a un solo n\u00famero destacado<\/td>\n<\/tr>\n<tr>\n<td>Tasa<\/td>\n<td>objetivos de disparo, emisi\u00f3n, adquisici\u00f3n y salida v\u00e1lida<\/td>\n<td>separa la frecuencia de la fuente de la tasa de datos del sistema<\/td>\n<\/tr>\n<tr>\n<td>\u00d3ptica de transmisi\u00f3n<\/td>\n<td>apertura, divergencia final, di\u00e1metro del haz, ventana<\/td>\n<td>conecta la divergencia de la fuente con el llenado del objetivo y la alineaci\u00f3n<\/td>\n<\/tr>\n<tr>\n<td>Receptor<\/td>\n<td>apertura, campo de visi\u00f3n, dispositivo InGaAs, filtro, ancho de banda<\/td>\n<td>completa el presupuesto de alcance<\/td>\n<\/tr>\n<tr>\n<td>Sincronizaci\u00f3n<\/td>\n<td>definici\u00f3n de disparo, referencia de emisi\u00f3n, precisi\u00f3n, latencia<\/td>\n<td>define la cadena de medici\u00f3n de distancia<\/td>\n<\/tr>\n<tr>\n<td>Mec\u00e1nico<\/td>\n<td>envolvente disponible, dato de referencia de montaje, l\u00edmite de masa, eje \u00f3ptico<\/td>\n<td>identifica restricciones de empaquetado y alineaci\u00f3n<\/td>\n<\/tr>\n<tr>\n<td>El\u00e9ctrico<\/td>\n<td>voltaje de la fuente, enfoque del driver, interfaz de control, ciclo de trabajo<\/td>\n<td>admite la integraci\u00f3n compatible de fuente y driver<\/td>\n<\/tr>\n<tr>\n<td>Entorno<\/td>\n<td>temperatura, vibraci\u00f3n, humedad, contaminaci\u00f3n, visibilidad<\/td>\n<td>define las condiciones de validaci\u00f3n<\/td>\n<\/tr>\n<tr>\n<td>Calificaci\u00f3n<\/td>\n<td>cantidad de prototipos, plan de prueba, l\u00edmites de aceptaci\u00f3n, pron\u00f3stico de producci\u00f3n<\/td>\n<td>alinea las muestras de desarrollo con un suministro escalable<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/figure>\n<\/div>\n\n<div class=\"wp-block-group alignfull has-background is-layout-constrained wp-container-core-group-is-layout-c12f9e37 wp-block-group-is-layout-constrained\" style=\"background-color:#f5f5f3;margin-top:0;margin-bottom:0;padding-top:72px;padding-right:24px;padding-bottom:72px;padding-left:24px\">\n\n<div class=\"wp-block-group lumexis-related has-background is-layout-constrained wp-container-core-group-is-layout-c48c1f9f wp-block-group-is-layout-constrained\" style=\"background-color:#f5f5f3;padding-top:clamp(26px,3.5vw,40px);padding-right:clamp(20px,3.5vw,36px);padding-bottom:clamp(26px,3.5vw,40px);padding-left:clamp(20px,3.5vw,36px)\">\n\n<h2 class=\"wp-block-heading\" style=\"font-size:clamp(24px,2.6vw,32px);font-weight:700;line-height:1.12\">Fuentes l\u00e1ser Lumexis compatibles<\/h2>\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:15px;line-height:1.6\">Transmisores Er:glass de 40 \u00b5J a 500 \u00b5J, para integradores que incorporan su propio receptor y temporizaci\u00f3n.<\/p>\n\n\n<ul class=\"wp-block-list\" style=\"font-size:15px;line-height:1.7\"><li><a href=\"https:\/\/lumexislaser.com\/es\/erbium-glass-lasers\/\">Fuentes l\u00e1ser Er:glass de 1535 nm \u2014 gama completa<\/a><\/li><li><a href=\"https:\/\/lumexislaser.com\/es\/1535nm-100uj-erbium-glass-laser-source\/\">Fuente de L\u00e1ser de Vidrio de Erbio 1535nm 100\u00b5J<\/a><\/li><li><a href=\"https:\/\/lumexislaser.com\/es\/1535nm-500uj-erbium-glass-laser-source\/\">Fuente de L\u00e1ser de Vidrio de Erbio 1535nm 500\u00b5J<\/a><\/li><li><a href=\"https:\/\/lumexislaser.com\/es\/laser-rangefinder-modules\/\">M\u00f3dulos tel\u00e9metros l\u00e1ser de 1535 nm \u2014 m\u00f3dulos completos en lugar de<\/a><\/li><\/ul>\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:15px;line-height:1.6\">Si necesita un canal de medici\u00f3n de distancia terminado en lugar de una fuente desnuda, consulte <a href=\"https:\/\/lumexislaser.com\/es\/solutions\/laser-ranging\/\">soluciones de medici\u00f3n l\u00e1ser<\/a>. Para revisar un presupuesto de alcance, <a href=\"https:\/\/lumexislaser.com\/es\/contact\/\">hable con un ingeniero de Lumexis<\/a>.<\/p>\n\n<\/div>\n\n\n<h2 class=\"wp-block-heading\" style=\"margin-top:0;margin-bottom:32px;font-size:clamp(30px,4vw,44px);font-weight:700;line-height:1.08\">Preguntas frecuentes<\/h2>\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>\u00bfEs una fuente l\u00e1ser de Er:vidrio de 1535 nm un tel\u00e9metro l\u00e1ser completo?<\/summary>\n<p class=\"wp-block-paragraph\">No. Es el emisor pulsado utilizado en el transmisor. Un tel\u00e9metro completo tambi\u00e9n necesita electr\u00f3nica de excitaci\u00f3n, \u00f3ptica de transmisi\u00f3n, un receptor, detector, electr\u00f3nica de temporizaci\u00f3n y detecci\u00f3n, alineaci\u00f3n mec\u00e1nica, una trayectoria \u00f3ptica externa y una interfaz de host.<\/p>\n<\/details>\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>\u00bfQu\u00e9 energ\u00eda de pulso deber\u00eda elegir para la medici\u00f3n de distancias largas?<\/summary>\n<p class=\"wp-block-paragraph\">Elija seg\u00fan un presupuesto de alcance, no solo por la distancia. Una mayor energ\u00eda de pulso puede a\u00f1adir margen al transmisor, pero el llenado del objetivo, la transmisi\u00f3n atmosf\u00e9rica, la apertura del receptor, la sensibilidad del detector, el fondo, el m\u00e9todo de sincronizaci\u00f3n y la probabilidad de detecci\u00f3n aceptable pueden ser igualmente decisivos. Env\u00ede esos datos para obtener una recomendaci\u00f3n significativa.<\/p>\n<\/details>\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>\u00bfEs 40 \u00b5J a 1000 Hz m\u00e1s d\u00e9bil que 500 \u00b5J a 10 Hz?<\/summary>\n<p class=\"wp-block-paragraph\">No es una comparaci\u00f3n \u00fatil de una sola palabra. La fuente de 500 \u00b5J entrega m\u00e1s energ\u00eda por pulso, lo que puede respaldar un retorno individual m\u00e1s fuerte. La fuente de 40 \u00b5J emite con m\u00e1s frecuencia y tiene una salida \u00f3ptica promedio nominal m\u00e1s alta a la tasa m\u00e1xima indicada. La elecci\u00f3n correcta depende de la tasa de adquisici\u00f3n, el retorno del objetivo, el comportamiento del detector, la potencia, el dise\u00f1o t\u00e9rmico y el m\u00e9todo de escaneo o muestreo.<\/p>\n<\/details>\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>\u00bfLa divergencia listada de 10\u201315 mrad equivale a la divergencia final del haz del tel\u00e9metro?<\/summary>\n<p class=\"wp-block-paragraph\">No necesariamente. Es la especificaci\u00f3n de salida de la fuente. El transmisor terminado normalmente utiliza \u00f3ptica de colimaci\u00f3n o expansi\u00f3n de haz para establecer el di\u00e1metro final del haz y la divergencia. El rendimiento final debe medirse despu\u00e9s de que el ensamblaje \u00f3ptico y mec\u00e1nico est\u00e9 alineado.<\/p>\n<\/details>\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>\u00bfPuede el ancho de pulso convertirse directamente en precisi\u00f3n de distancia?<\/summary>\n<p class=\"wp-block-paragraph\">No. El ancho de pulso es parte del problema de temporizaci\u00f3n, pero la precisi\u00f3n tambi\u00e9n depende de la forma de onda, el detector y el ancho de banda electr\u00f3nico, la relaci\u00f3n se\u00f1al-ruido, el umbral de temporizaci\u00f3n, la calibraci\u00f3n, la profundidad del objetivo y las condiciones ambientales. Utilice la precisi\u00f3n medida del sistema bajo las condiciones de prueba indicadas.<\/p>\n<\/details>\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>\u00bfPuede Lumexis personalizar la fuente para un instrumento OEM?<\/summary>\n<p class=\"wp-block-paragraph\">Lumexis puede revisar los requisitos espec\u00edficos del proyecto para la salida \u00f3ptica, el modo de repetici\u00f3n, la integraci\u00f3n del paquete, el montaje, la compatibilidad del controlador, el uso ambiental, las pruebas y el suministro de producci\u00f3n. La viabilidad y las especificaciones finales se confirman mediante revisi\u00f3n de ingenier\u00eda.<\/p>\n<\/details>\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>\u00bfQu\u00e9 tecnolog\u00eda de receptor se utiliza com\u00fanmente a 1535 nm?<\/summary>\n<p class=\"wp-block-paragraph\">Los fotodiodos de InGaAs y los fotodiodos de avalancha se utilizan ampliamente en la regi\u00f3n de 1,5 \u00b5m. La selecci\u00f3n del detector tambi\u00e9n debe tener en cuenta el \u00e1rea activa, la ganancia, el ancho de banda, el ruido, la luz de fondo, la temperatura, la saturaci\u00f3n y el m\u00e9todo de temporizaci\u00f3n.<sup id=\"fnref2:hamamatsu\"><a class=\"footnote-ref\" href=\"#fn:hamamatsu\">2<\/a><\/sup><\/p>\n<\/details>\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>\u00bfQu\u00e9 datos se deben recopilar durante las pruebas de prototipos?<\/summary>\n<p class=\"wp-block-paragraph\">Registre la configuraci\u00f3n de la fuente, la energ\u00eda del pulso, el ancho del pulso, el modo de repetici\u00f3n, la referencia de emisi\u00f3n, el objetivo, la distancia, el \u00e1ngulo del objetivo, la atm\u00f3sfera, la \u00f3ptica de transmisi\u00f3n, los ajustes del receptor, la temperatura, el comportamiento del suministro, el estado de detecci\u00f3n bruto y la salida de rango v\u00e1lido. Esto hace que las fallas sean diagnosticables y las comparaciones repetibles.<\/p>\n<\/details>\n<\/div>\n\n<div class=\"wp-block-group alignfull has-background is-layout-constrained wp-container-core-group-is-layout-c12f9e37 wp-block-group-is-layout-constrained\" style=\"background-color:#ffffff;margin-top:0;margin-bottom:0;padding-top:72px;padding-right:24px;padding-bottom:72px;padding-left:24px\">\n<h2 class=\"wp-block-heading\" style=\"margin-top:0;margin-bottom:32px;font-size:clamp(30px,4vw,44px);font-weight:700;line-height:1.08\">Solicite una recomendaci\u00f3n de fuente<\/h2>\n\n<p class=\"wp-block-paragraph\">Env\u00ede a Lumexis su aplicaci\u00f3n, objetivo, envolvente de distancia, tasa requerida, apertura de transmisi\u00f3n, divergencia final, concepto de receptor, l\u00edmites de tama\u00f1o y masa, rango de temperatura, cantidad de prototipos y cronograma. Nuestros ingenieros ayudar\u00e1n a asignar el proyecto a la plataforma de 40\u2013500 \u00b5J e identificar\u00e1n las cuestiones \u00f3pticas, de temporizaci\u00f3n y de calificaci\u00f3n que deben resolverse antes de la producci\u00f3n.<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>CTA sugerido:<\/strong> Solicite una recomendaci\u00f3n de fuente l\u00e1ser de medici\u00f3n de distancia de 1535 nm.<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>CTA secundario:<\/strong> Comparta su presupuesto de alcance para revisi\u00f3n de ingenier\u00eda.<\/p>\n\n<p class=\"wp-block-paragraph\">Lumexis: fuentes l\u00e1ser de precisi\u00f3n, dise\u00f1adas para el mundo real.<\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<\/div>\n\n<div class=\"wp-block-group alignfull has-background is-layout-constrained wp-container-core-group-is-layout-c12f9e37 wp-block-group-is-layout-constrained\" style=\"background-color:#f5f5f3;margin-top:0;margin-bottom:0;padding-top:72px;padding-right:24px;padding-bottom:72px;padding-left:24px\">\n<h2 class=\"wp-block-heading\" style=\"margin-top:0;margin-bottom:32px;font-size:clamp(30px,4vw,44px);font-weight:700;line-height:1.08\">Referencias t\u00e9cnicas<\/h2>\n\n<h3 class=\"wp-block-heading\" style=\"margin-top:34px;margin-bottom:16px;font-size:clamp(21px,2.4vw,28px);font-weight:650;line-height:1.25\">Antecedentes t\u00e9cnicos adicionales consultados<\/h3>\n\n<ul class=\"wp-block-list\">\n<li>G. J. Sp\u00fchler et al., \u201cExperimentally confirmed design guidelines for passively Q-switched microchip lasers using semiconductor saturable absorbers,\u201d proporciona antecedentes generales sobre la generaci\u00f3n de pulsos; no documenta la construcci\u00f3n interna de los productos de Lumexis. <a href=\"https:\/\/opg.optica.org\/abstract.cfm?uri=josab-16-3-376\" target=\"_blank\" rel=\"noopener\">Registro de art\u00edculo de Optica<\/a><\/li>\n<li>R. H\u00e4ring et al., \u201cPassively Q-switched microchip laser at 1.5 \u00b5m,\u201d proporciona antecedentes revisados por pares sobre emisores pulsados compactos en esta regi\u00f3n de longitud de onda; Lumexis no infiere una arquitectura id\u00e9ntica a partir de esta fuente. <a href=\"https:\/\/opg.optica.org\/josab\/abstract.cfm?uri=josab-18-12-1805\" target=\"_blank\" rel=\"noopener\">Registro de art\u00edculo de Optica<\/a><\/li>\n<\/ul>\n\n<div class=\"footnote\">\n<hr\/>\n<ol>\n<li id=\"fn:nasa-tof\">\n<p>Centro de Vuelo Espacial Goddard de la NASA, <em>El Sistema L\u00e1ser de Altimetr\u00eda Geocient\u00edfica: C\u00f3mo la altimetr\u00eda l\u00e1ser mide la distancia<\/em>. <a href=\"https:\/\/science.gsfc.nasa.gov\/attic\/glas\/human.html\" target=\"_blank\" rel=\"noopener\">Descripci\u00f3n t\u00e9cnica educativa<\/a>\u00a0<a class=\"footnote-backref\" href=\"#fnref:nasa-tof\" title=\"Volver a la nota al pie 1 en el texto\">\u21a9<\/a><\/p>\n<\/li>\n<li id=\"fn:hamamatsu\">\n<p>Hamamatsu Photonics, <em>APDs de InGaAs para medici\u00f3n de distancia y aplicaciones LiDAR<\/em>. <a href=\"https:\/\/www.hamamatsu.com\/us\/en\/product\/optical-sensors\/distance-position-sensor\/lidar-sensor\/ingaas-apd.html\" target=\"_blank\" rel=\"noopener\">Descripci\u00f3n general de producto y t\u00e9cnica<\/a>\u00a0<a class=\"footnote-backref\" href=\"#fnref:hamamatsu\" title=\"Volver a la nota al pie 2 en el texto\">\u21a9<\/a><a class=\"footnote-backref\" href=\"#fnref2:hamamatsu\" title=\"Volver a la nota al pie 2 en el texto\">\u21a9<\/a><\/p>\n<\/li>\n<li id=\"fn:glas-link\">\n<p>Investigaci\u00f3n de NASA\/ICESat, <em>Mediciones de altimetr\u00eda ICESat\/GLAS: Rango din\u00e1mico de se\u00f1al recibida y correcci\u00f3n de saturaci\u00f3n<\/em>. <a href=\"https:\/\/pmc.ncbi.nlm.nih.gov\/articles\/PMC6110114\/\" target=\"_blank\" rel=\"noopener\">Art\u00edculo de acceso abierto<\/a>\u00a0<a class=\"footnote-backref\" href=\"#fnref:glas-link\" title=\"Volver a la nota al pie 3 en el texto\">\u21a9<\/a><\/p>\n<\/li>\n<\/ol>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Seleccione una fuente l\u00e1ser Er:glass de 1535 nm por aplicaci\u00f3n, energ\u00eda de pulso, tasa de repetici\u00f3n, ancho de pulso y divergencia para integraci\u00f3n de medici\u00f3n de distancia ToF de precisi\u00f3n.<\/p>","protected":false},"author":3,"featured_media":901,"parent":11,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-902","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/lumexislaser.com\/es\/wp-json\/wp\/v2\/pages\/902","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lumexislaser.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/lumexislaser.com\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/lumexislaser.com\/es\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/lumexislaser.com\/es\/wp-json\/wp\/v2\/comments?post=902"}],"version-history":[{"count":5,"href":"https:\/\/lumexislaser.com\/es\/wp-json\/wp\/v2\/pages\/902\/revisions"}],"predecessor-version":[{"id":1782,"href":"https:\/\/lumexislaser.com\/es\/wp-json\/wp\/v2\/pages\/902\/revisions\/1782"}],"up":[{"embeddable":true,"href":"https:\/\/lumexislaser.com\/es\/wp-json\/wp\/v2\/pages\/11"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/lumexislaser.com\/es\/wp-json\/wp\/v2\/media\/901"}],"wp:attachment":[{"href":"https:\/\/lumexislaser.com\/es\/wp-json\/wp\/v2\/media?parent=902"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}